(+98) 21 66965659-60
(+98) 21 66965657
info@fcgostar.com

EN 12591:2009

European product standards cover a large variety of road materials for different applications, to accommodate local traffic loads and climate conditions. This European standard therefore also covers a large range of bitumens to facilitate the production and application of the designed paving. The variety of production techniques and applications makes it more practical to split bitumens into 20/30, 30/45, 35/50, 40/60, 50/70, 70/100, 100/150, 160/220.  Fouman Chimie Gostar is capable of producing the following grades:

  • 35-50:

Characteristic

Unit

35-50

Test Method

Penetration @ 25  °C

dmm

35-50

EN 1426

Softening Point

°C

50-58

EN 1427

Resistance to Hardening @163 °C:

Retained Penetration

Change of Mass

 

%

%

 

53 min

0.5 max

 

EN 12607-1

 

Flash Point

°C

240 min

EN ISO 2592

Solubility

%

99.0 min

EN 12592

Penetration Index

-

-1.5 to +0.7

EN 12591-Annex A

Dynamic Viscosity @ 60 °C  

Pa.S

225 min

EN 12596

Fraass Breaking Point

°C

-5 max

EN 12593

Kinematic Viscosity @ 135 °C  

cSt

370 min

EN 12595


  • 50-70:

Characteristic

Unit

50-70

Test Method

Penetration @ 25  °C

dmm

50-70

EN 1426

Softening Point

°C

46-54

EN 1427

Resistance to Hardening @163 °C:

Retained Penetration
Change of Mass

 

%

%

 

50 min

0.5 max

 

EN 12607-1

 

Flash Point

°C

230 min

EN ISO 2592

Solubility

%

99.0 min

EN 12592

Penetration Index

-

-1.5 to +0.7

EN 12591-Annex A

Dynamic Viscosity @ 60  °C

Pa.S

145 min

EN 12596

Fraass Breaking Point

°C

-8 max

EN 12593

Kinematic Viscosity @ 135 °C 

cSt

295 min

EN 12595


  • 70-100:

Characteristic

Unit

70-100

Test Method

Penetration @ 25  °C

dmm

70-100

EN 1426

Softening Point

°C

43-51

EN 1427

Resistance to Hardening @163 °C:

Retained Penetration
Change of Mass

 

%

%

 

46 min

0.8 max

 

EN 12607-1

 

Flash Point

°C

230 min

EN ISO 2592

Solubility

%

99.0 min

EN 12592

Penetration Index

-

-1.5 to +0.7

EN 12591-Annex A

Dynamic Viscosity @ 60  °C

Pa.S

90 min

EN 12596

Fraass Breaking Point

°C

-10 max

EN 12593

Kinematic Viscosity @ 135 °C  

cSt

230 min

EN 12595


  • 100-150:

Characteristic

Unit

100-150

Test Method

Penetration @ 25 °C 

dmm

100-150

EN 1426

Softening Point

°C

39-47

EN 1427

Resistance to Hardening @163 °C:

Retained Penetration
Change of Mass

 

%

%

 

43 min

0.8 max

 

EN 12607-1

 

Flash Point

°C

230 min

EN ISO 2592

Solubility

%

99.0 min

EN 12592

Penetration Index

-

-1.5 to +0.7

EN 12591-Annex A

Dynamic Viscosity @ 60 °C 

Pa.S

55 min

EN 12596

Fraass Breaking Point

°C

-12 max

EN 12593

Kinematic Viscosity @ 135 °C 

cSt

175 min

EN 12595


  • 160-220:

Characteristic

Unit

160-220

Test Method

Penetration @ 25 °C 

dmm

160-220

EN 1426

Softening Point

°C

35-43

EN 1427

Resistance to Hardening @163 °C:

Retained Penetration

Change of Mass

 

%

%

 

37 min

1.0 max

 

EN 12607-1

 

Flash Point

°C

220 min

EN ISO 2592

Solubility

%

99.0 min

EN 12592

Penetration Index

-

-1.5 to +0.7

EN 12591-Annex A

Dynamic Viscosity @ 60 °C 

Pa.S

30 min

EN 12596

Fraass Breaking Point

°C

-15 max

EN 12593

Kinematic Viscosity @ 135 °C  

cSt

135 min

EN 12595


© 2015 FCG Limited. All rights reserved